4-160 Datafilling ISDN on RSC-S UK / Europe
ISDN operations
Datafilling table LTCINV for ISDN on RSC-S International
Subfield or
Field
refinement
TONESET
PROCPEC
E2LOAD
PEC6X40
Note 1: When the table supports NI-1, make sure that the user entered ISP in the OPTCARD. The
ISP is the designator of the enhanced EISP (NTBX01BA) card.
Note 2: Make changes to fields with multiple entries in the PROMPT mode.
297-8331-815 Standard 10.01 August 1999
(continued)
Entry
UK100
MX77AA
MX77AA
alphanumeric
6X40AC
(continued)
Description
TONESET. Enter UK100. Range of values
includes DEFAULT, NORTHAM and UK100.
Processor equipment product engineering
codes. One PEC is necessary for each PLGC
or LGCO unit. Enter the PEC for unit 0 first.
The PEC must reflect the minimum firmware
capabilities in the processor complex of each
unit.
EEPROM loadfile name. Contains the name of
the loadfile loaded in the NTMX77AA EEPROM.
For 6X40 equipment PEC. Enter the version of
the NT6X40 to be used. The 6X40AC is the
required version for ISDN.
—end—