Nortel DMS-100 Series Reference Manual page 113

Extended peripheral module
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

Datafill example for table ALMSCGRP
Sample datafill for table ALMSCGRP appears in the following example.
MAP display example for table ALMSCGRP
Datafilling table ALMSDGRP
Table alarm signal distributor group (ALMSDGRP) records circuit
equipment, location, and circuit pack type that contains SD points. Refer to
the data schema section of the Translations Guide for a description of the
other fields.
Datafilling table ALMSDGRP
Subfield or
Field
refinement
SDGRP
TMTYPE
TMNO
TMCKTNO
CARDCODE
DMS-100 Family XPM International Translations Reference Manual XPM12 and up
Table: ALMSCGRP
SCGROUP TMTYPE TMNO TMCKTNO CARDCODE
––––––––––––––––––––––––––––––––––––––––
0
MTM
1
MTM
2
MTM
3
MTM
.
.
.
.
.
.
21
RMM
Entry
0 to 255
MTM, OAU,
RMM
0 to 255
0 to 23
refer to list
Datafilling BAS on RSC-S International
Basic call processing
1
1
3X82AA
3
1
3X82AA
1
7
3X84AA
1
10
0X10AA
.
.
.
.
.
.
2
11
0X10AA
Explanation and action
Signal distributor group. Enter the signal
distributor group number.
Trunk module type. Enter type of trunk module
where the circuit mounts.
Trunk module number Enter the number of the
trunk module where the circuit mounts.
Trunk module circuit number Enter the trunk
module circuit number where the circuit is
assigned.
Card code. Enter the PEC of the alarm card.
Values: 3X82AA, 3X84AA, and 2X57AA.
(continued)
.
.
.
3-89

Advertisement

Table of Contents
loading

Table of Contents