Adding PPXLs to a current PM load lineup
Use the following procedure to add PPXLs to a current XPM load
alignment:
1 Verify that all patch_ids associated with the PPXL are present on the
disk volume that field ACTVOL in table PMLOADS identifies. If any
patch_ids are not present, copy the patches from tape to the correct
volume. The PM tape shipment contains a list of the patches in each
PPXL. After you copy the PPXLs to disk, list the patches in the PPXL.
To list the patches in the PPXL, type
>XPMLFP
and press the Enter key.
>PATCHLIST FILE ppxl_filename
and press the Enter key.
where
ppxl_filename
2 Copy the PPXL file (filename_date) to the disk volume used in step 1.
3 Copy the baseload to the disk volume in table PMLOADS, field
BKPVOL.
4 Modify table PMLOADS. If the XPM base loadname is not present in
table PMLOADS, use the previous procedure, Upgrading baseload
lineup to add a new tuple. Under any other conditions, change the
ACTFILE field to the PPXL filename (filename_date). At this point, the
system upgrades the loadset if the loadset is present. The system creates
a loadset if the loadset is not present.
5 To set the loadset against both units of the XPM, type
>PATCHER
and press the Enter key.
>SET loadname PM pm_type device_no unit_no
and press the Enter key.
where
loadname
is the name of the loadfile
pm_type
is the type of PM that requires the loadset
device_no
is the device number with a range of 0-255
unit_no
is the unit number, 0 or 1
DMS-100 Family XPM International Translations Reference Manual XPM12 and up
Firmware downloading
is the filename of the PPXL loaded to disk