4-204 Datafilling Firmware downloading on RSC-S UK / Europe
Firmware downloading
6 To load each unit of the XPM with the PPXL, type
7 Perform a SWACT of the XPM and repeat step 6.
297-8331-815 Standard 10.01 August 1999
(continued)
>BSY UNIT unit_no
and press the Enter key.
>LOADPM UNIT unit_no
and press the Enter key.
>RTS UNIT unit_no
and press the Enter key.
where
unit_no
is the unit number of the XPM to load
Note 1: When loaded, the XPM can have additional patches applied or
removed by the same method used with previous XPM loads. You can
remove any patches built in the PPXL from the load. You can remove
the patches if the actual patch file is present on disk.
Note 2: The system can add or remove PPXLs after the load of a PPXL
occurs. The system can apply and remove these PPXLs after subsequent
reloads of the PPXL occur.