3-172 Datafilling ISDN on RSC-S International
ISDN operations
Datafilling table LTCPSINV
Subfield or
Field
refinement
LTCNAME
XPMTYPE
LTCNAME
XPMNO
(continued)
PSLNKTAB
PSLINK
Note 1: Enter the subfields in PSDATA depending on the AREASELCT chosen value. If
AREASELCT is DS30A, DCH, or NILTYPE, no other fields require datafill. If PSDATA is D30, fill in
subfields CARRIDX and ACTION.
Note 2: You can define only three DCHs in ports 1, 9, and 17 in an RCO2 main shelf without an
extension cabinet. You can define an additional seven DCHs in an RCO2 with an extension cabinet.
A DCH is allowed on links 1, 9, 10–15, and 17–21.
Note 3: A PCM-30 is not allowed on ports 1–8, 9–15, and 17–21, in the order given, if the following
condition exists. The DCH is on link 1, 9, or 17.
297-8331-815 Standard 10.01 August 1999
(continued)
Entry
see subfields
PLGC
0 to 255
see subfields
1, 9, 17
—continued—
Explanation and action
Line trunk controller name. Subfields:
XPMTYPE and XPMNO.
PM type. Contains the same entry in field
XPMTYPE of table LTCINV. Use PLGC for both
ISDN and non-ISDN RSC-S.
Note: An LGCO+ is always entered as a
PLGC.
PM number. Contains the unit number of the
PLGC in field XPMNO of table LTCINV.
P-side link table. Subfields: PSLINK, PSDATA,
and CONTMARK.
Note: Make changes to fields with multiple
entries in the PROMPT mode only.
Vector of P-side ports. Enter the P-side port
number to enter. The DCH must be entered in
odd ports.