Nortel DMS-100 Series Reference Manual page 503

Extended peripheral module
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

Remote Switching Center Multi-access (RSC-M)
Datafilling table RCCINV
Subfield or
Field
refinement
EXTINFO
EXTSIDE
(continued)
Note 1: For each RSC-M that table RCCINV defines, table RCCPSINV defines a corresponding
tube to allow PCM30 links to be entered on the RSC-M P-side. The PCM30 link numbers that
correspond to the EXT shelf can be entered if table RCCINV defines the EXT.
Note 2: Before the switch deletes a main or EXT shelf from an RSC-M in table RCCINV, the switch
must delete the P-side links from the main or EXT shelf from table RCCPSINV.
Note 3: Make changes to fields with multiple entries in the PROMPT mode.
Note 4: When you enter data in field C-side link table (CSLNKTAB), make sure message links are
not assigned to the same physical interface card. When the interface card supports two or more
links, separate the message links by the number of links on the interface cards. This applies to
interface link types; DS-1, DS30, DS30A, or PCM-30. Table control issues a warning if an attempt
to assign message links occurs on the same interface card. The assignment of message links to
the same interface card can cause an E1 outage (failure of all message links) if the card fails.
Note: The tuples in table RCCINV change through the addition of the
subfield EXT_INFO. Subfield EXT_INFO helps to define extension
shelves.
DMS-100 Family XPM International Translations Reference Manual, ISN06 (TDM)
Datafilling Remote Switching Center Multi-Access 5-43
(continued)
Entry
L or R
—end—
Description
Extension shelf side. This field defines the EXT
half shelf, left or right side.
(continued)