Nortel DMS-100 Series Reference Manual page 128

Extended peripheral module
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

3-104 Datafilling BAS on RSC-S International
Basic call processing
The datafill for basic call processing for table REXSCHED appears in the
following table. The only fields that are shown apply directly to basic call
processing. Refer to the data schema section of the Translations Guide for a
description of the other fields.
Datafilling table REXSCHED
Subfield or
Field
refinement
REXTSTID
REX_TEST_ID
ENABLE
PERIOD
PARALLEL
Note: Application of this table is limited to REX test controllers for series 3 peripherals, applications
and file processors. Only the REX tests available are entered. Where there are no REX tests
available, the REXSCHED table is empty.
297-8331-815 Standard 10.01 August 1999
(continued)
Entry
Explanation and action
REX test identifier. The system automatically
defines REXSTIDS. Only REX tests available
in the office are shown.
see list
REX test ID. The system automatically defines
REX test identifiers when inventory tables are
datafilled. Examples: MS_REX_TEST,
CM_REX_TEST, SLM_REX_TEST,
LGC_REX_TEXT, RCO2_REX_TEST,
LCM_REX_TEST, and LCMCOV_REX_TEST.
N or Y
Enable. Enter either N or Y to disable or
enable the REX test. The default value is Y.
1 through 7
Period. Enter a number between 1 and 7 to
represent the minimum number of days
between two consecutive REX tests. The REX
tests are on the same object. Each test must
be run once a week. The range is 1 to 7. The
default value is 1.
1 through 99
Parallel. Limits the number of REX tests that
can occur in parallel for one group. The user
can choose to limit the number of parallel REX
tests within a group. The default value is set to
the maximum number allowed. The
maintenance software for each REX test
defines the maximum number allowed. This
value is determined by the resources required
for each test. The range is 1 to 99.
—continued—