Remote Switching Center Multi-access (RSC-M)
Datafilling table CARRMTC
Subfield or
Field
refinement
ATTR
LLFARST
(continued)
LLMAOST
LLMARST
RFAIOST
Note 1: The DMS switch adds the first tuple for the RSC-M to table CARRMTC during IPL or first
restart after IPL. The CAS is SIGNTYPE of the default tuple and the switch cannot delete or change
this tuple.
Note 2: Add tuples other than the default tuple before the tuples can be referenced in the table
RCCPSINV.
Note 3: Out-of-service timers in the AMC must be greater than the equivalent timers in the DMS
switch.
Note 4: Return-to-service timers in the AMC must be smaller than the equivalent timers in the DMS
switch.
DMS-100 Family XPM International Translations Reference Manual, ISN06 (TDM)
Datafilling Remote Switching Center Multi-Access 5-35
(continued)
Entry
numeric
(0 to 255)
30=3 sec
numeric
(0 to 255)
30=3 sec
numeric
(0 to 255)
30=3 sec
numeric
(0 to 255)
30=3 sec
—continued—
Description
Local loss of frame alignment RTS. Enter the
local loss of frame alignment RTS time limit.
This value appears in units of 100 ms.
The default value for this field is 30.
Local loss of multiframe alignments OOS time.
Enter the local loss of multiframe alignments
OOS time limit. This value appears in units of
100 ms.
The default value for this field is 30.
Local loss of multiframe alignment RTS time.
Enter local loss of multiframe alignment RTS
time limit. This value appears in units of
100 ms.
The default value for this field is 30.
Remote frame alignment indication OOS time.
Enter the remote frame alignment indication
OOS time. This value appears in units of
100 ms.
The default value for this field is 30.
(continued)