3-180 Datafilling ISDN on RSC-S International
ISDN operations
Datafilling table ISGDEF
Subfield or
Field
refinement
ISGNO
PMTYPE
PMNO
SERVICE
Note: For DCH sparing, do not enter the card to use as the spare in this table. Not enough datafill
in table ISGDEF automatically causes the system to spare the card.
297-8331-815 Standard 10.01 August 1999
(continued)
Entry
0 to 255
RCO2
0 to127
see list
—continued—
Explanation and action
Integrated services group number. Enter the
number of the D-channel handler card in the
PM.
PM type. Enter the PM that supports the DCH
services. Enter PLGC, LGCI, LTCI, or RCO2.
Peripheral module number.
Service. Enter the services provided by the
ISG; the entry value range is either basic rate
access (BRA) or packet data (PD).