3-150 Datafilling ISDN on RSC-S International
ISDN operations
DEFAULT_BEARER_CAPABILITY
This parameter defines the default bearer capability (BC) of an office. The
default is SPEECH. A change in the default can have an important impact
on call completion. If the value changes to 3_1KHZ, investigate table
RTECHAR for any entries that use a BC of speech. Use value 3_1KHZ be
only in a controlled environment. Make use of A-Law for national ISDN
(NI-2) compatible speech and 3.1 kHz bearer services. Use these services
on the PLGC and the RCO2.
Changing office parameters
Northern Telecom sets the default value of parameters during load build.
Use the following procedure to change an office parameter through the table
editor. The following procedure change the MAX_BRA_LINES parameter
in table OFCOPT.
1 To access table OFCOPT and position on the parameter, type
2 To request a change of the parameter to the desired value, type
3 To enter the new value, type
4 To confirm the change, type
5 To quit the table editor, type
For more information about how to enter office parameters, refer to Office
Parameters Reference Manual.
297-8331-815 Standard 10.01 August 1999
(continued)
>TABLE OFCOPT;POS MAX_BRA_LINES
>CHA
>n
where
n is the new parameter value
>Y
>QUIT
Note: When office parameters change, reload static data. To propagate
the parameter changes to the RCO2, reload static data with the following
command:
>LOADPM unit_no CC