Advertisement

5-34 Datafilling Remote Switching Center Multi-Access
Remote Switching Center Multi-access (RSC-M)
Datafilling table CARRMTC
Subfield or
Field
refinement
RTSML
RTSOL
ATTR
SELECTOR
CARD
VOICELAW
NATLBIT
LLFAOST
Note 1: The DMS switch adds the first tuple for the RSC-M to table CARRMTC during IPL or first
restart after IPL. The CAS is SIGNTYPE of the default tuple and the switch cannot delete or change
this tuple.
Note 2: Add tuples other than the default tuple before the tuples can be referenced in the table
RCCPSINV.
Note 3: Out-of-service timers in the AMC must be greater than the equivalent timers in the DMS
switch.
Note 4: Return-to-service timers in the AMC must be smaller than the equivalent timers in the DMS
switch.
297-8331-815 Standard 10.02 March 2004
(continued)
Entry
numeric
(0–255)
numeric
(0–255)
see subfield
D30
MX82AA
A_LAW
NATL or
INTERNATL
numeric
(0 to 255)
30=3 sec
—continued—
(continued)
Description
RTS maintenance limit. Enter the number of
times in the audit interval that a carrier the
system RTS before the system issues a
warning.
An entry of 255 disables this feature.
RTS OOS limit. Enter the number of times in
the audit interval that the system can RTS a
carrier before the carrier is permanently OOS.
An entry of 255 disables this feature.
Attribute. This field consists of subfield
SELECTOR and refinements.
Selector. For RSC-M enter D30.
Card. Enter the PEC of the PCM30 interface
card.
Voice law. Enter the voice law used in the
carrier. A_LAW is used for international
switches
National bit. Enter INTERNATL if the national
bit is international.
Local loss of frame alignment OOS time. Enter
the local loss of frame alignment OOS time
limit. This value appears in units of 100 ms.
The default value for this field is 30.