Nortel DMS-100 Series Reference Manual page 315

Extended peripheral module
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

Datafilling table RCCINV
Subfield or
Field
refinement
EXTSHELF
Note: When you enter field C-side link table (CSLNKTAB), make sure message links are not
assigned to the same interface card. When the interface card supports a minimum of two links,
separate the message links by the number of links on the interface cards. This action applies to all
interface link types. The interface link types are DS-1, DS30, DS30A, or PCM-30. Table control
issues a warning when you attempt to assign message links on the same interface card. If you
assign message links to the same interface card, an E1 outage can occur if the card fails. An E1
outage is a failure of all message links.
DMS-100 Family XPM International Translations Reference Manual XPM12 and up
(continued)
Entry
Y or N
Refer to
subfields
—end—
Datafilling BAS on RSC-S UK / Europe 4-65
Basic call processing
Explanation and action
Extension shelf. Enter Y if the CPM has an
extension shelf. If Y, the refinements to this
field appear below.
Enter the location of the extension shelf in the
following fields:
EXTFRTYP
EXTFRNO
EXTSHPOS
EXTFLOOR
EXTROW
EXTFR
POS
EXTEQPEC
EXTSIDE (L or R)
(continued)