Datafilling Firmware downloading on RSC-S International 3-215
6 To set the loadset against both units of the XPM, type
>PATCHER
and press the Enter key.
>SET loadname PM pm_type device_no unit_no
and press the Enter key.
where
loadname
is the name of the loadfile
pm_type
is the type of PM requiring the loadset
device_no
is the device number with a range of 0–255
unit_no
is the unit number, 0 or 1
7 To load the PPXL into each unit of the XPM, type
>BSY UNIT unit_no
and press the Enter key.
>LOADPM UNIT unit_no
and press the Enter key.
>RTS UNIT unit_no
and press the Enter key.
where
unit_no
is the unit number of the XPM to load
8 Perform a SWACT of the XPM and repeat step 7.
Note 1: After you load the XPM, the XPM can have additional patches
applied or removed like past XPM loads. You can remove any patches
built into the PPXL from the load as long as the actual patch file is on
disk.
Note 2: Any patches that the system automatically applies or removes
following loading of a PPXL the system will automatically apply or
remove on reloads of the PPXL.
Note 3: Patches that are not PPXL patches are not removed when you
reload the PPXL. There is no need to remove these patches because the
removed patches are already out of the loadset.