Nortel DMS-100 Series Reference Manual page 327

Extended peripheral module
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

Datafilling table Line Circuit Inventory (LNINV)
Table LNINV defines the site, line equipment number, and associated data
for each line card circuit. The system can add or delete table LNINV line
datafill for remote fiber terminal (RFT) lines in an S/DMS AccessNode
system. The system can use SERVORD to perform this action. This
auto-create feature removes a manual provisioning step. The feature allows
RFT line cards to be software-provisioned and service-provisioned in a
single step. For additional information, refer to SERVORD Reference
Manual.
Datafilling table LNINV
Subfield or
Field
refinement
LEN
SITE
FRAME
UNIT
LSG
CIRCUIT
CARDCODE
PADGP
DMS-100 Family XPM International Translations Reference Manual XPM12 and up
Datafilling BAS on RSC-S UK / Europe 4-77
Basic call processing
Entry
Explanation and action
refer to
Line Equipment Number. Contains the
subfields
following subfields:
SITE
FRAME
UNIT
LSG
CIRCUIT
alpahnumeric
Site. Enter the site assigned to the remote
location.
0 to 99
Frame. The range is 0–99.
0 to1
Unit. The range is 0–1.
0 to 19
Line Subgroup. For LCMs the range is 0–19.
0 to 31
Circuit. Enter the circuit number of the line
card. The range is from 0–31.
alphanumeric
Cardcode. Enter the correct line card for the
office. The EBS line card (6X21AC) or
advanced UDLC line card (6X21AD).
character
Pad Group. Enter the name of the pad group
assigned to the line circuit in table PADDATA.
—continued—
(continued)

Advertisement