Note 9: The system dynamically allocates memory for this table to a
maximum of 2000 tuples.
Datafilling table MTAHORIZ
Subfield or
Field
refinement
HORIZ
HORIZGRP
HORIZAGT
SELECTOR
DMS-100 Family XPM International Translations Reference Manual XPM12 and up
Datafilling BAS on RSC-S UK / Europe 4-99
Basic call processing
Entry
Explanation and action
0 to 127
The MTA horizontal. Enter the MTA horizontal
where the test equipment (horizontal agent)
connects.
0 to 159
The MTA horizontal group. Enter the horizontal
group number that identifies the horizontal and
the agent of the horizontal as a specified tuple.
The horizontal group allows assignment of
different test equipment on the same MTA
horizontal.
refer to
This field contains several subfields. The value
subfields
of SELECTOR determines the subfields.
1 to 2
Selector. The range is S, L, T, B, E, MJ, J, and
characters
LA.
Enter S for a timed short circuit.
Enter L for LTU or MTU assignment and
complete subfields CLLI, EXTRKNM, and
ALTUSE.
Enter T for incoming test access or operator
verification trunk assignment and complete
subfields CLLI and EXTRKNM.
Enter B for a board-to-board dedicated
horizontal and complete subfield BBTNR.
Enter E to multiply a horizontal of a minibar
switch from a host or remote to the vertical of a
host minibar switch. Complete subfield
EMTAVERT.
Enter MJ for metal connection to the tip and ring
of the subscriber line. Complete subfields CLLI
and MJACKNUM.
Selectors J and LA are for licensee use only.
(continued)