Translations table flow
The basic call processing translation process appears in the flowchart that
follows the table descriptions.
Table CLLI identifies the far end of the trunk group by:
Table CLLI stores the maximum number of trunk groups expected to be
assigned to the trunk group. Table CLLI also stores a miscellaneous entry
for administrative information the switching unit does not use.
The system adds some CLLI codes to table CLLI when the feature is present
in the switch. Add other codes to table CLLI. After you enter table CLLI,
CLLI codes are reflected in trunk group tables, the scan and distribution
point table, and MTA tables. Duplicate the CLLI tuple for operator
verification in field OPVRCLLI in table SITE.
Table PMLOADS stores the device location of every peripheral module
(PM) load file. The PMLOADS stores the location to map between the load
names and devices where loads reside. You must enter PM load files in
table PMLOADS before you can use PM load files in the inventory tables.
Enter load information in field LOADNAME. Enter corresponding entries
in field LOAD for tables LTCINV, LCMINV and RMMINV.
Table SITE identifies equipment for the switching unit and for the remote
locations that use the switching unit. You must enter data in table SITE
before you can assign a LEN or enter data in a PM. The host switching unit
is the first entry in field NAME. Field LTDSN associates with the number
required to dial the site and alarm data for remote sites. Table SITE uses the
same CLLI tuple for operator verification as the CLLI tuple you entered in
table CLLI.
DMS-100 Family XPM International Translations Reference Manual XPM12 and up
the name of the city or town
the state or province
the building group
the destination of the traffic unit
the code that identifies trunk groups that terminate at the same CLLI
location
Note: Enter some data tables according to the kind of trunk group type
required. Each trunk group type requires a specified form. Valid trunk
group types are TI, TO, T2, IBNTI, IBNTO, IBNT2, PX and ES.
Datafilling BAS on RSC-S International 3-25
Basic call processing
(continued)