Datafilling office parameters
The office parameters that ISDN operations uses appear in the following
table. Refer to Office Parameters Reference Manual for more information
about office parameters.
Office parameters by ISDN on RSC-S International
Table
Parameter name
name
OFCENG
DCH_BD_STATMUX_RATIO
OFCOPT
MAX_BRA_LINES
OFCOPT
MAX_PRI_LINKS
OFCVAR
ISDN_PERFORMANCE_MON_ALARM
OFCVAR
DAILY_ISDN_LAYER2_PEG_AUDIT_
TIME
OFCENG
DEFAULT_BEARER_CAPABILITY
Datafill sequence
The tables that require datafill to operate ISDN on RSC-S appear in the
following table. The tables appear in the order in which to enter the tables.
DMS-100 Family XPM International Translations Reference Manual XPM12 and up
Datafilling ISDN on RSC-S International 3-161
ISDN operations
Explanation and action
Controls the maximum number of LTs that
can multiplex on one Bd channel. The
default maximum is 64. Do not set the
maximum value to greater than 32 unless
the packet handler can handle more than
32.
Specifies the maximum number of basic
rate access (BRA) lines that can be
assigned. Range: 0 to 10000.
Default: 10.
Set equal to the number of primary rate
interface (PRI) links if the links have the
PRI package installed on a link basis.
Generates an ISDN performance
monitoring LINE131 logs.
Sets the time of day to collect and reset
layer 2 peg counts for ISDN200 and
ISDN201 logs. Use the 24-hour clock.
Defines the bearer capability (BC) of the
office with ISDN capabilities.
Default: SPEECH.