Advertisement

Remote Switching Center Multi-access (RSC-M)
Datafilling table RCCPSINV
Subfield or
Field
refinement
RCCNAME
XPMTYPE
XPMNO
PSLNKTAB
EXP
P-SIDES
EXP TAB
PSLINK
PSDATA
Note: Before the switch can delete an EXT from an RSC-M, the switch must delete the P-side links
that belong to the EXT (that change to NILTYPE).
DMS-100 Family XPM International Translations Reference Manual, ISN06 (TDM)
Datafilling Remote Switching Center Multi-Access 5-45
Entry
Description
refer to
Link trunk controller. This field consists of
subfield
subfields XPMTYPE and XPMNO.
RCO2
External peripheral module type. Enter the
extended multi-processor system PM type
RCO2.
0–255
External peripheral module number. Enter the
PM number.
refer to
P-side link table. You can enter a maximum of
subfield
46 PCM30 links in a RSC-M. The default is
NILTYPE. This field consists of subfield EXP
P-SIDES.
Y
Expanded P-side platform indicator. If the entry
in field XPMTYPE is RSC-M, enter Y (yes) and
datafill field EXP TAB.
refer to
Expansion table. This field consists of subfields
subfield
PSLINK and PSDATA.
0–47
P-side link. This field defines the number of
P-side ports. For RSC-M, enter 0-47.
Note: P-side links 22 and 23 are reserved.
D30
P-side data. This field describes P-side link
type.
—continued—
(continued)