3-188 Datafilling ISDN on RSC-S International
ISDN operations
The Bb-channel connection provides packet data service on a B-channel.
The connection is between a B1 or B2 channel on a line card and a PCM-30
channel to the PH.
The B-channel to B-channel connection is between a B1 or B2 channel on a
line card to another B1 or B2 channel. The end points are on separate
LCMEs with an access privilege (AP) of PB.
Table SPECCONN is the table used to route different PCM-30 links to the
packet handler. You can nail up the links through the PLGC.
This table changes to accommodate an RCO2 entry in PMTYPE, a subfield
of SCSEL. You can define the PCM-30 end point of the RCO2 shelf in
ports higher than 19, a maximum of 47.
The datafill example for table SPECCONN shows only the fields that apply
to the ISDN on RSC-S. Refer to the data schema section of the Translations
Guide for a description of the other fields.
Datafilling table SPECCONN
Subfield or
Field
refinement
ENDPT1
SCSEL
ENDPT1
(continued)
PMTYPE
DEQNO
DEQCKTNO
DEQCKTTS
297-8331-815 Standard 10.01 August 1999
(continued)
Entry
see subfields
see list
D30
PLGC
0 to 511
0 to 19
1 to 31
—continued—
Explanation and action
End point 1. Identifies the first end point.
Contains subfield SCSEL and refinements.
End point selector. Enter the type of selector
for the end point. Enter D30, ISLC, or
DCHCHNL.
If you enter SCSEL D30, subfield PMTYPE
determines the fields to complete.
PM type. Entries are PLGC or RCO2. If entry
is PLGC, enter subfields DEQNO, DQCKTNO,
and DEQCKTTS. See entry for RCO2.
DEQNO. Enter external number of the PM.
DEQCKTNO. This is the PM circuit number.
Enter P-side port of the PM.
DEQCKTTS. Enter the time slot (channel) on
the PCM-30.