3-36 Datafilling BAS on RSC-S International
Basic call processing
Example of OFCENG table MAP display
Parameter TALK_BATTERY_ALARM
This parameter turns on the automatic audits of the talk battery in
LCM/XLCM/LCME/RLCM/OPM/OPAC peripheral modules. When this
parameter changes, activation is immediate.
Datafilling table CLLI
The CLLI codes identify the far end of each announcement, tone, trunk
group, test trunk, national milliwatt test lines and service circuit.
The following table describes the entries specific to basic call processing for
table CLLI. Fields that apply directly to basic call processing appear in the
table. The example that appears is for other than a Gateway Switching
Center. Refer to the data schema section of the Translations Guide for a
description of the other fields.
Datafilling table CLLI
Subfield or
Field
refinement
CLLI
PLACE
Note 1: The maximum number of CLLI codes is 8192.
Note 2: The SIZE field in table DATASIZE allocates memory for entry with field DATSKEY equal to
CLLI.
297-8331-815 Standard 10.01 August 1999
(continued)
Table OFCENG
PARMNAME
––––––––––––––––––––––––––––––––––––––––––––––
TALK_BATTERY_ALARM
Entry
refer to
subfields
alphanumeric
Description
Common language location identifier. This
16-character field identifies the far end of each
announcement, tone, trunk group, test trunk,
national milliwatt test lines and service circuit.
The recommended subfields are PLACE,
PROV, BLDG, TRAFUNIT and SUFX.
Place. This 4-character code identifies the
name of the city or town at the far end of each
group.