4-56 Datafilling BAS on RSC-S UK / Europe
Basic call processing
Datafilling table CARRMTC
Subfield or
Field
refinement
AIS16OST
AIS16RST
AIS16ML
AIS16OL
CRC4
CRE
CRCOST
CRCRST
CRCML
CRCOL
IDLECODE
297-8331-815 Standard 10.01 August 1999
(continued)
(continued)
Entry
0 to 255
0 to 255
0 to 255
0 to 255
Y or N
Y or N
0 to 255
0 to 255
0 to 1023
0 to 1023
Q503 or
G714
—continued—
Explanation and action
Return-to-service time for AIS16 alarm. The
default is 4.
Return-to-service time for AIS16 alarm. The
default is 4.
Maintenance limit for AIS16 alarm. The default
is 17.
Out-of-service limit for AIS16 alarm. The
default is 255.
Initiate the cyclic redundancy check 4 (CRC4)
routine.
Initiates the CRE procedure.
Out-of-service time for cyclic redundancy check
(CRC) alarm. The default is 5.
Return-to-service time for CRC alarm. The
default is 5.
Maintenance limit for CRC4 alarm. The default
is 205.
Out-of-service limit for CRC4 alarm. The
default is 914.
The CCITT recommended Idle channel bit
pattern.