Nortel DMS-100 Series Reference Manual page 299

Extended peripheral module
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

Datafilling table LTCINV
Subfield or
Field
refinement
PEC6X40
EXTINFO
Note 1: Make changes to fields with multiple entries in the PROMPT mode. In nonprompt mode,
you can leave out present entries.
Note 2: Enter the continuation mark (+) in fields with multiple possible entries when more data is
specified on the next line or more records are entered. Enter the end mark ($) in fields with multiple
possible entries after the last entry.
Example of entries for table LTCINV
The following example describes sample entries for table LTCINV.
MAP display example for table LTCINV
Table: LTCINV
LTCNAME
________________________________________________________
PLGC 1
EXECTAB
________________________________________________________
(POTS POTSEX)(KEYSET KSETEX)(RMM_TERM RSMEX)(ABTRK DTCEX)
CSLNKTAB
________________________________________________________
(9 17)(13 61)(5 14)(0 29)(1 30)(2 31)(3 28)(4 29)
OPTCARD
________________________________________________________
(UTR6)(ISP)(RAM6X69)(7X05)(CMR18 CMRAG03)
TONESET
________________________________________________________
AUS100
DMS-100 Family XPM International Translations Reference Manual XPM12 and up
(continued)
Entry
alphanumeric
—end—
FRTYPE FRNO SHPOS FLOOR ROW FRPOS EQPEC
LGE
1
PROCPEC
MX77AA
MX77AA
Datafilling BAS on RSC-S UK / Europe 4-49
Basic call processing
Description
The 6X40 equipment PEC. Enter the version of
the NT6X40 to be used.
EXTENSION_INFO.
18
0
C
6
CMRLOAD
E2LOAD
OPATTR
MX77NH08
$
(continued)
LOAD
6X02AG
KRI06AY
$
$
PEC6X40
6X40AC