3-10 Introduction to RSC-S International

Configurations

The RSC-S configuration can occur with or without ISDN. An RSC-S
configuration has a family of peripherals that are not ISDN. This
configuration provides a wide range of services. These services do not
include ISDN services. An RSC-S with ISDN provides all the services of
the RSC-S. An RSC-S with ISDN can include all the peripherals of the
RSC-S. This configuration includes ISDN peripherals and provides ISDN
services.
The configuration type affects datafill requirements because the
configuration determines the services available with the RSC-S.

Activating the RSC-S

Enter the field operator verification common language location identifier
(OPVRCLLI) in table CLLI first for RSC-S. This tuple in table CLLI forms
a field in table SITE. Enter other tables in the order that the data schema
section of the Translations Guide. specifies.

When to update the RCO2 static data

Update static data in the RCO2 when the following conditions occur:

Alarms produced when a static data mismatch occurs

An update of the static data for the central control (CC) at the CC can occur.
This update occurs when an update of the static data at the RCO2 does not
occur. When this condition occurs, the system generates a PM128 log with
the following message:
STATIC DATA MISMATCH WITH CC
297-8331-815 Standard 10.01 August 1999
the addition, change or deletion of links on the RCO2 P-side or C-side in
tables RCCINV, RCCPSINV, or LTCPSINV
the addition, change or deletion of nodes off the RCO2 or links
associated with these nodes in tables LCMINV, RMMINV, or
RCCPSINV
the addition, change or deletion of cards in the card list of the RCO2 or
nodes off the RCO2 in tables LCMINV, RMMINV, or RCCPSINV
the addition, change or deletion of exec data for the RCO2 in table
RCCINV
a global office parameter that affects the RSC-S configuration changes
when ESA is turned on or off in table RCCINV
Note: The NODATASYNC option is the method of preference.