Nortel DMS-100 Series Reference Manual page 280

Extended peripheral module
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

4-30 Datafilling BAS on RSC-S UK / Europe
Basic call processing
Activation/deactivation by the end user
Basic call processing does not require activation or deactivation by the end
user.
Billing
Basic call processing does not affect billing.
Station Message Detail Recording
Basic call processing does not affect Station Message Detail Recording.
Datafilling office parameters
The basic RSC-S configuration does not have specified parameters. The
RSC-S configuration can have RSC-2 capabilities like emergency
stand-alone (ESA). The chapters on RSC-2 capabilities discuss each
capability.
Parameter LCDREX _CONTROL in table OFCVAR transfers control of
routine exercise (REX) tests for line concentrating modules (LCM). The
tests of LCM ring and voltage values, previously a section of LCM_REX,
becomes part of an LCM converter test (LCM_COV_REX). Control of
LCM_REX_TEST and LCMCOV_REX_TEST, part of system REX
(SREX), transfer to parameter NODEREXCONTROL in table OFCVAR.
Parameter LCDREX_CONTROL remains to control REX testing of line
modules (LM).
Note: The system performs the LCMCOV_REX_TEST on LCMs, XLCMs,
OPMs, and RLCMs.
Data entry sequence
The following table lists the tables that require data for Basic call
processing. Enter data in the tables in the order that the tables appear in the
list.
297-8331-815 Standard 10.01 August 1999
(continued)

Advertisement

Table of Contents
loading

Table of Contents