Nortel DMS-100 Series Reference Manual page 158

Extended peripheral module
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

3-134 Datafilling PCM-30 trunks on RSC-S International
PCM-30 R1 Trunking
Datafilling table CARRMTC
The data entry for PCM-30 R1 Trunking for table CARRMTC appears in the
following table. The fields that appear apply to PCM-30 R1 Trunking.
Refer to the data schema section of the Translations Guide for a description
of the other fields.
Datafilling table CARRMTC
Subfield or
Field
refinement
CSPMTYPE
TMPLTNM
Datafill example for table CARRMTC
The following is an example of data entry for PCM-30 RC-S R1 trunking in
table CARRMTC.
MAP example for table CARRMTC
Datafilling table RCCINV
Table remote cluster controller inventory (RCCINV) contains inventory
data, except P-side link assignments, for the RCO2. The following
procedure describes data entry for table RCCINV. The fields that appear
apply to PCM-30 R1 Trunking. Refer to the data schema section of the
Translations Guide for a description of the other fields.
297-8331-815 Standard 10.01 August 1999
(continued)
Entry
RCO2
DEFAULT
Table: CARRMTC
CSPMTYPE TMPLTNM RTSML RTSOL
–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
RCO2 DEFAULT 255 255 D30 NTMX82AA A_LAW INTERNATL 100 100 150 150 200
200 220 220 50 50 50 50 100 100 100 120 120 130 130 140 140 100 200 200
Y 4 4 17 255 Y Y 5 5 205 914 G714 D30RCC
Explanation and action
C-side node PM type. Enter the PM type of the
node on the C-side of the carrier link.
Template name. Enter the template name for
the PM. The template name is a maximum of
16 characters. This entry appears in field
CARRIDX in table LTCPSINV.
ATTR

Advertisement

Table of Contents
loading

Table of Contents