Cabinetized Remote Switching Center (Crsc) Cabinet - Nortel DMS-100 Series Reference Manual

Extended peripheral module
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

The RSC-S can contain the following:
a maximum of two CRSC cabinets
a minimum of one cabinetized power distribution centers (CPDC)
one cabinetized extension module (CEXT)
a maximum of five cabinetized line concentrating equipment (CLCE)
cabinets
a minimum of one cabinetized miscellaneous equipment (CMIS)
cabinets
a miscellaneous spares storage (CMSS) cabinet that stores spare cards

Cabinetized remote switching center (CRSC) cabinet

A single-configuration RSC-S can have one CRSC cabinet that contains:
one provisioned RCO2 shelf
one remote maintenance module (RMM) that dedicated DS30A links
serve
one LCME
the model type determines the following:
— one frame supervisory panel (FSP), when model A
— one modular supervisory panel (MSP), when model B
Note: A software upgrade does not occur on the MAP display. The
upgrade indicates the difference between model A frame alarms and
model B cabinet alarms. These alarm types indicate FSP at the MAP
terminal.
DMS-100 Family XPM International Translations Reference Manual XPM12 and up
Introduction to RSC-S International 3-3