3.2 Message Detail Data

This paragraph describes the detailed information on the faults indicated by system messages (message detail
data).
3.2.1

Message Detail Data of System Message "4-R"

System Message 4-R: TCP/IP Link Failure
(1) Print-out Format
SYSTEM MESSAGE 4 - R
NEC - ESD
1: xx xx
xx xx
1
2
3
(2) Print-out information (typical)
1
Fault port number:
2
Communication Protocol:
3
Error Code (ERRK):
2
PROTOCOL
03
(ETHER + TCP/IP)
13 (0D) ~ 255 (FF) Not used
This error code shows that the Host (UAP) is down manually. You can program not to output this detail
Note 4:
message at some offices using SYS1, INDEX864, b1 in ASYDL (Other messages than ERRK = 01 is output
when TCP connection disconnected is not output).
4
Fault logical channel number (LCID): 01~10H (00 means the data is invalid)
00 00
00 00
4
3
ERROR CODE
01
TCP Connection disconnected (Normal)
12 (0C)
Abnormal UAP is detected by Heart Beat function
Relation between LCID and Node TCP port number
LCID
01
CHAPTER 8
2: 00 00
00 00
0-5
03 = ETHER + TCP/IP
Refer to the table below
CONTENT OF FAULT
TCP port number of the Node
60030
– 364 –
SYSTEM MAINTENANCE
TCP/IP Link Failure
DEC 22 21:32
00 00
00 00
Note 1