(6) When a DID Trunk is managed by multiple ACDPs, the trunk information (CA, AF message) is sent
to each MIS. Accordingly, the number of originating static report which is concerned with the trunk
group and the trunk to be processed by the other ACDPs is included in the report.
(7) When new node (nodes) is added to the network, the node that accommodates ACDP must be initial-
ized.
(8) When multiple Agent Anywhere networks are activated via tandem connection of FCCS links, each
controlling nodes should not be control the one's Agent Anywhere nodes across the node of the other
Agent Anywhere Network, because of excess Node-to Node load.
Multiple Agent Anywhere Networks via tandem connection of FCCS links
RECOMMENDED
Agent Anywhere
Network A
Node
Node
FCCS
FCCS
B
A
NOT RECOMMENDED
Agent Anywhere Network B
Node
Node
FCCS
FCCS
B
A
Agent Anywhere Network A
(9) When ACD system is not operated normally after the assignment of monitor number data, broadcast
the VNDM data by using the CBCV command. By using the CBCV command, the VNDM data can
be broadcast to all the VNDM Local nodes in an FCCS network from the VNDM Center node.
Agent Anywhere
Network B
Node
Node
FCCS
C
D
Node
Node
FCCS
C
D
– 100 –
CHAPTER 4
NOT RECOMMENDED
Agent Anywhere
Network B
Node
Node
FCCS
FCCS
B
A
Agent Anywhere Network A
OFFICE DATA DESIGN
Node
Node
FCCS
C
D