Night Service - NEC Univerge SV8500 Programming Manual

Hide thumbs Also See for Univerge SV8500:
Table of Contents

Advertisement

NAP-215-114
Sheet 1/2

Night Service

For IP/SIP terminal
LAN
Split C
D: ATT
A
B
START
Use one of the following three methods to change into the night mode.
(1) Automatic changeover into the night mode based on the ACD call control vector (Night Announce-
ment setting using ACD CCV command).
(2) Pressing the NIGHT key on the supervisory position of split C; as this display confirmation message
Night Mode?, enter 1# to change over into the night mode.
(3) Changeover into the night mode by means of operation at the MIS terminal of the supervisory
position.
Night Announcement
• Place a C.O. trunk call from station A to line B in the special night split.
Station A hears the night announcement.
Apply the test procedure above to all splits.
Using the ACD CCV command, change the night services of the split and test each of the following
services repeatedly.
A
CHAPTER 5
ACD SERVICE FEATURES FUNCTIONAL TEST PROCEDURES
SP
IP PAD
Announcement
Trunk
ATI
LC
Announcement Trunk
COT
Split C
D: ATT
– 285 –
For Digital terminal
ELC/DLC
ELC/DLC
ATI
LC
A
B
COT