Overview of the CP-Parameters
Parameter
CP.0
Password input
CP.1
Actual frequency display
CP.2
Set frequency display
CP.3
Inverter status
CP.4
Apparent current
CP.5 Apparent current peak value
CP.6
Utilization
CP.7
DC link voltage
CP.8 DC link voltage peak value
CP.9
Output voltage
CP.10 Minimal frequency
CP.11 Maximum frequency
CP.12 Acceleration time
CP.13 Deceleration time (-1=CP.12)
CP.14 S-curve time
CP.15 Boost
CP.16 Rated frequency
CP.17 Voltage stabilization
CP.18 Switching frequency
CP.19 Fixed frequency 1
CP.20 Fixed frequency 2
CP.21 Fixed frequency 3
CP.22 DC braking mode
CP.23 DC braking time
CP.24 Max. ramp current
CP.25 Max. constant current
CP.26 Speed search condition
CP.27 Motor protection response
CP.28 Motor protection mode
CP.29 Motor protection rated current
CP.30 Analog output function
CP.31 Analog output amplification
CP.32 Transistor output function
CP.33 Relay output function
CP.34 Relay output switching level
CP.35 Set value selection
CP.36 Select 50/60Hz mode
CP.37 Response to external overtemperature 0...7
LTK=depending on power unit; E=ENTER parameter
1)
The CP-Parameter group is a selection of more than 500 parameters and 8 parameter
sets for simple applications. Each CP-Parameter (not CP.00) can be individually assigned so
a special final customer menue is generated. Further documentation is specified at the end
of this manual.
Parameter Description
Resolu-
Setting Range
0...9999
-400...400
0.0125
-400...400
0.0125
0...255
0...6553.5
0...6553.5
0...65535
0...1000
0...1000
0...778
0...400
0.0125
0...400
0.0125
0.00...300.00
-0.01...300.00
0,00...5,00
0.0...25.5
0...400
0.0125
0...649 V, oFF
0...LTK
-400...400
0.0125
-400...400
0.0125
-400...400
0.0125
0...9
0.00...100.00
0...200
0...200
0...15
0...6
0...1
0.0...370.0
0...26
-20.00...20.00
0...86
0...86
±30000.00
0...2
0...1
Default Unit ↵
tion
1
-
-
-
0 Hz -
0 Hz -
1
0
-
-
0.1
0 A
-
0.1
0 A
-
1
0 %
-
1
0 V
-
1
0 V
-
1
0 V
-
0 Hz -
70 Hz -
0.01
5 s
-
0.01
5 s
-
0.01
0 s
-
0.1
LTK %
-
50 Hz -
1
off V
E
1
LTK
-
E
5 Hz -
50 Hz -
70 Hz -
1
7
-
E Pn.28
0.01
10 s
-
1
140 %
-
1 200:off %
-
1
8
-
E Pn.26
1
6 –
– Pn.14
1
1 –
0.1
LTK A
1
2 –
E an.31
0.01
1 –
1
20 –
E do.00
1
4 –
E do.02
0.01 100.00 –
1
0 –
E An.00
1
0 –
E ud.06
1
7
-
-
based
on
ud.1
ru.3
ru.1
ru.0
ru.15
ru.16
ru.13
ru.18
ru.19
ru.20
oP.6
oP.10
oP.28
oP.30
oP.32
uF.1
uF.0
uF.9
uF.11
op.21
op.22
op.23
Pn.30
Pn.24
Pn.20
dr.11
dr.12
an.33
Le.02
Pn.12
GB - 31