Parameter Description For Multi And Application With Encoder Interface - KEB Combivert F5 series Installation Manual

5.5...7.5kw 230v 4.0...15kw 400v
Hide thumbs Also See for Combivert F5 series:
Table of Contents

Advertisement

CP-Parameter
5.2

Parameter description for Multi and Application with encoder interface

Display Parameter
CP.00 Password Input
CP.01 Encoder 1 speed
CP.02 Setpoint display
CP.03 Inverter state
CP.04 Apparent current
CP.05 Apparent current / peak value
CP.06 Actual torque
CP.07 Actual DC voltage
CP.08 DC-link voltage / peak value
CP.09 Output voltage
CP.10 Speed control configuration
CP.11 DASM Rated speed
CP.12 DASM rated frequency
CP.13 DASM rated current
CP.14 DASM Rated voltage
CP.15 DASM Rated cos (phi)
CP.16 DASM Rated power
CP.17 Load motor dependent parameter
CP.18 Boost
CP.19 rated frequency
CP.20 Encoder 1 (inc/r)
CP.21 Encoder 1 rotation
CP.22 Maximum speed
CP.23 Step value 1
CP.24 Step value 2
CP.25 Acceleration time
CP.26 Deceleration time
CP.27 S-curve time
CP.28 Torque reference source
CP.29 Absolute torque reference
CP.30 KP speed
CP.31 KI speed
CP.32 Switching frequency
CP.33 Relay output 1 / Function
CP.34 Relay output 2 / Function
CP.35 Limit switch / stopping mode
CP.36 External Fault / stopping mode
CP.3
Inverter status
In parameter „inverter status" the actual operating condition of the frequency inverter is
displayed (e.g. constant running forward, standstill). In the case of an error the current error
message is displayed, even if the display has already been reset with ENTER (error-LED
on the operator is still blinking). Status messages and information about the cause and
removal are to be found in "www.keb.de".
GB - 30
Setting range
Resolution Default
0...9999
±4000
0.125
±4000
0.125
0...255
0...6553.5
0.1
0...6553.5
0.1
±10000.00
0.01
0...1000
0...1000
0...778
0(off)...5
0...32000
0.0...1600.0
0.1
0.0...1100.0
0.1
120...830
0.50...1.00
0.01
0.10...1000.00
0.01
0...3
0.0...25.5
0.1
0...400
0.0125
1...65535
0...19
0...4000
0.125
±4000
0.125
±4000
0.125
0.00...300.00
0.01
-0.01...300.00
0.01
0.00(off)...5.00
0.01
0...6
±32000,00
0.01
0...32767
0...32767
1...LTK
0...92
0...92
0...6
0...6
Unit ENTER Based on
1
0
rpm
0
rpm
1
0
0
A
0
A
0
Nm
1
0
V
1
0
V
1
0
V
1
0 (off)
1
LTK
rpm
LTK
Hz
LTK
A
1
LTK
V
LTK
LTK
kW
1
1
LTK
%
50
Hz
1
2500
Inc
1
0
2100
rpm
100
rpm
-100
rpm
5,00
s
5,00
s
0.00(off)
s
1
2
LTK
Nm
1
300
1
100
1
LTK
1
4
1
2
1
6
1
0
ud.01
ru.09
ru.01
ru.00
ru.15
ru.16
ru.12
ru.18
ru.19
ru.20
cs.00
dr.24
dr.25
dr.23
dr.02
dr.04
dr.03
E
fr.10
uf.01
uf.00
E
ec.01
E
ec.06
op.10
op.21
op.22
op.28
op.30
op.32
E
cs.15
cs.19
cs.06
cs.09
E
uf.11
E
do.02
E
do.03
pn.07
pn.03

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Combivert f5

Table of Contents