Parameter Description - KEB COMBIVERT F5 Instructions For Use Manual

Installation f5 profinet operator
Hide thumbs Also See for COMBIVERT F5:
Table of Contents

Advertisement

PARAMETER DEScRIPTION

7.2 Parameter description
ID:
Name:
Meaning
Parameter number (PNU):
Subindex:
Data type:
Coding:
Standard value:
Note:
ID:
Name:
Meaning
Parameter number (PNU):
Subindex:
Data type:
Coding:
Standard value:
Note:
ID:
Name:
Meaning
Parameter number (PNU):
Subindex:
Data type:
Coding:
Standard value:
Note:
OS00
Operator type
Indicates the operator type and the software version.
0180h
0
Uint32
11800 + software version as two-digit decimal number with 1 decimal place
in the least significant two decimal places.
Depending on actual software version
Example: 11828: F5 PROFINET operator with software V2.8.
OS01
Password
Indicates the actual adjusted password level of the operator software.
0181h
0
Int16
KEB internal
Level4 password
Written and countercheck value are not identical. Currently the password
level has no effect on the functionality of the operator and thus has no impor-
tance for the user.
OS02
Software date
Indicates the software date of the actual software.
0182h
0
Uint32
First 4 decimal places = year
Next 2 decimal places = month
Last 2 decimal places = day
Depending on the actual software version date
Example: Value = 20120503 : 03.05.2012 is displayed in COMBIVIS as plain-
text as ‚2012,0503':
37