Renesas H8 Series Hardware Manual page 409

8-bit single-chip microcomputer
Hide thumbs Also See for H8 Series:
Table of Contents

Advertisement

Start receive
[4]
error processing
OER = 1?
No
FER = 1?
No
PER = 1?
No
Clear bits OER, PER,
FER to 0 in SSR
End of receive
error processing
Figure 10.8 Example of Data Reception Flowchart (Asynchronous Mode) (cont)
Overrun error
processing
Yes
Break?
Yes
No
Framing error
Yes
processing
Parity error
processing
Section 10 Serial Communication Interface
[4]
If a receive error has
occurred, read bits OER,
PER, and FER in SSR to
identify the error, and after
carrying out the necessary
error processing, ensure
that bits OER, PER, and
FER are all cleared to 0.
Yes
Reception cannot be
resumed if any of these
bits is set to 1. In the case
of a framing error, a break
can be detected by reading
the value of the RXD
(A)
Rev. 7.00 Mar 10, 2005 page 367 of 652
pin.
32
REJ09B0042-0700

Advertisement

Table of Contents
loading

Table of Contents