Omron Sysmac NY-series Instruction & Reference Manual page 519

Industrial pc platform, motion control
Hide thumbs Also See for Sysmac NY-series:
Table of Contents

Advertisement

Contents of Inline ST
//MC_MoveVelocity parameters
Vel_Vel := LREAL#1000.0;
Vel_Acc := LREAL#0.0;
Vel_Dec := LREAL#0.0;
Vel_Jrk := LREAL#1000.0;
InitFlag := BOOL#TRUE;
//MC_DigitalCamSwitch parameters
Switches[0].TrackNumber := UINT#0;
Switches[0].FirstOnPosition := LREAL#2000.0;
Switches[0].LastOnPosition := LREAL#3000.0;
Switches[0].AxisDirection := _eMC_DIRECTION#_mcPositiveDirection;
Switches[0].CamSwitchMode := _eMC_SWITCH_MODE#_mcPositionBased;
Switches[1].TrackNumber := UINT#0;
Switches[1].FirstOnPosition := LREAL#2500.0;
Switches[1].LastOnPosition := LREAL#3000.0;
Switches[1].AxisDirection := _eMC_DIRECTION#_mcNegativeDirection;
Switches[1].CamSwitchMode := _eMC_SWITCH_MODE#_mcPositionBased;
Switches[2].TrackNumber := UINT#0;
Switches[2].FirstOnPosition := LREAL#4000.0;
Switches[2].LastOnPosition := LREAL#1000.0;
Switches[2].AxisDirection := _eMC_DIRECTION#_mcNoDirection;
Switches[2].CamSwitchMode := _eMC_SWITCH_MODE#_mcPositionBased;
Switches[3].TrackNumber := UINT#1;
Switches[3].FirstOnPosition := LREAL#3000.0;
Switches[3].Duration := T#1350ms;
Switches[3].AxisDirection := _eMC_DIRECTION#_mcNoDirection;
Switches[3].CamSwitchMode := _eMC_SWITCH_MODE#_mcTimeBased;
Structured Text (ST)
 Main Variables
Name
MC_Axis000
MC_Axis001
E001_Time_Stamp_of_Synchronous_Output
N3_Output_Bit_00
N3_Output_Bit_00_Time_Stamp
N3_Output_Bit_01
N3_Output_Bit_01_Time_Stamp
NY-series Motion Control Instructions Reference Manual (W561)
3 Axis Command Instructions
Data type
Default
_sAXIS_REF
---
_sAXIS_REF
---
ULINT
---
BOOL
---
ULINT
---
BOOL
---
ULINT
---
Comment
Axis Variable for axis 1.
Axis Variable for axis 2.
*1
Device variable
Device variable
Device variable
Device variable
Device variable
3-431
3

Advertisement

Table of Contents
loading

Table of Contents