MC_GearOut

The MC_GearOut instruction stops operation for the MC_GearIn (Start Gear Operation) instruction or
MC_GearInPos (Positioning Gear Operation) instruction.
Instruction
Name
MC_GearOut
End Gear
Operation

Variables

Input Variables
Name
Meaning
Execute
Execute
Deceleration
Decelera-
tion Rate
Jerk
Jerk
(Reserved)
OutMode
Sync End
(Reserved)
Mode Se-
lection
*1.
Refer to Unit Conversion Settings in the NY-series Industrial Panel PC / Industrial Box PC Motion Control User's
Manual (Cat. No. W559) for information on command units.
*2.
The default value for an enumeration variable is actually not the number, but the enumerator.
Output Variables
Name
Meaning
Done
Done
Busy
Executing
NY-series Motion Control Instructions Reference Manual (W561)
FB/
Graphic expression
FUN
FB
MC_GearOut_instance
MC_GearOut
Slave
Execute
Deceleration
Jerk
OutMode
Data type
Valid range
BOOL
TRUE or FALSE
LREAL
Non-negative number
LREAL
_eMC_OUT_MODE
0: _mcStop
Data
Valid
type
range
BOOL
TRUE or
FALSE
BOOL
TRUE or
FALSE
3 Axis Command Instructions
MC_GearOut_instance (
Slave :=parameter,
Execute :=parameter,
Slave
Done
Deceleration :=parameter,
Busy
Jerk :=parameter,
CommandAborted
OutMode :=parameter,
Error
Done =>parameter,
ErrorID
Busy =>parameter,
CommandAborted =>parameter,
Error =>parameter,
ErrorID =>parameter
);
De-
fault
FALS
The instruction is executed when
E
the value of this variable changes
to TRUE.
0
Specify the deceleration rate.
The unit is command units/s
0
0
(Reserved)
(Reserved)
*2
0
Description
TRUE when the instruction is completed.
TRUE when the instruction is acknowledged.
ST expression
Description
2
*1
.
3-289
3