NY-series Motion Control Instructions Reference Manual (W561)
Data type
Default
BOOL
FALSE
This variable is assigned to the Active output
variable from the VEL instance of the
MC_MoveVelocity instruction. It is TRUE during
velocity control by the VEL instance.
LREAL
0
This is the velocity override factor.
BOOL
FALSE
When this variable is TRUE, MC_Stop is exe-
cuted.
BOOL
FALSE
TRUE when chemical solution supply is detect-
ed.
If the Servo is ON for axis 1, the MC_MoveVe-
locity (Velocity Control) instruction is executed.
BOOL
FALSE
If this variable is TRUE, the override factor is
set to 500%. After this variable changes to
TRUE, it remains TRUE until Sensor3 changes
to TRUE, at which time it changes to FALSE.
BOOL
FALSE
If this variable is TRUE, the override factor is
set to 200%. After this variable changes to
TRUE, it remains TRUE.
BOOL
FALSE
The VEL instance of MC_MoveVelocity is exe-
cuted when this variable changes to TRUE.
BOOL
FALSE
The SET_OV instance of MC_SetOverride is
executed while this variable is TRUE.
BOOL
FALSE
The STP instance of MC_Stop is executed
when this variable changes to TRUE.
BOOL
FALSE
This variable indicates if it is necessary to set
the input parameters.
Input parameters are set when this variable is
FALSE. When setting the input parameters is
completed, this variable changes to TRUE.
3 Axis Command Instructions
Comment
3
3-99