Checking The Sole1 Operation - FujiFilm PROFECT CS Service Manual

Table of Contents

Advertisement

12.5

Checking the SOLE1 Operation

1.
Remove the top cover.
{MC:3.1_Covers}
2.
Place the RU in the Maintenance Mode.
Start the User Utility.
{MU:2.2.1_Starting the User Utility}
3.
Start the MUTL.
{MU:5.2.1_Starting the MUTL}
4.
Select Erasure Conveyor 2.
5.
Turn ON the path change guide (SOLF1).
6.
Turn OFF the path change guide (SOLF1).
011-202-04
11.15.2004 FM4425
7.
Check the result of the operation via the LEDs.
l Checking the result of the operation
If an error code is displayed on the MUTL, instead of "RESULT-OK", then refer to
the error code table and troubleshoot again.
{MT:2._Error Code Table}
l Checking the display of the LEDs
Check the display of the LEDs located on the DRV17B board.
The LEDs can only be checked corresponding to the timing of the path change
guide (SOLE1) activation.
If they cannot be checked, repeat steps 4 through 7 again to check them.
If the LEDs can be checked during activation of the actuator (which may be
checked via the sound generated by it, for example), it may be judged that the
path change guide (SOLE1) is normal.
8.
Exit the MUTL.
{MU:5.2.2_Exiting the MUTL}
9.
Reinstall the top cover.
{MC:3.1_Covers}
CR-IR 363 Service Manual
MT-229
MT-229

Advertisement

Table of Contents
loading

This manual is also suitable for:

Clearview csClearview csmCr-ir 363