Error
Error Name
Code
Post-erasure path guide status
10362
error (2)
10363
Load IP conveyance error (4)
10364
Load IP conveyance error (2)
10365
Load IP conveyance error (3)
10369
Path guide HP detection error
Path guide changeover detection
10371
error
Convergence path guide HP
10372
positioning error
011-202-04
11.15.2004 FM4425
During bootup/routine processing, the IP transport motor (ME1, MB1, MB2) is driven to convey the IP to the cassette
after the IP is erased, and the pre-BCR IP sensor (SB5) transitions to CLOSE; however, the IP feed/load sensor
(SB1/2/3/4) for other than the shelf of interest transitions to CLOSE.
During bootup/routine processing, the IP transport motor (ME1, MB1, MB2) is driven to convey the IP to the feed/
load conveyor unit after the IP is erased; however, the pre-BCR IP sensor (SB5) does not transition to OPEN within
the specified period of time.
During bootup/routine processing/abnormality processing, the IP transport motor (MB1, MB2) is driven to convey the
IP to the cassette; however, the IP feed/load sensor (SB1/2/3/4) for the shelf of interest does not transition to OPEN
within the specified period of time.
During abnormality processing, the IP transport motor (MB1, MB2, MC3) is driven to eject the IP to the cassette;
however, the IP feed/load sensor (SB1/2/3/4) does not transition to OPEN within the specified period of time.
During bootup/routine processing/M-Utility, the convergence path changeover guide drive motor (MB3) is driven to
perform home-positioning of the path changeover guide (feed/load conveyor unit); however, the path changeover
shelf sensor (SB7/8/9) and path changeover HP sensor (SB11) do not transition to CLOSE within the specified
period of time, resulting in a retry (twice or more).
During bootup/routine processing/M-Utility, the convergence path changeover guide drive motor (MB3) is driven to
perform path changeover operation (feed/load conveyor unit); however, the path changeover shelf sensor (SB7/8/9)
and path changeover HP sensor (SB11) do not transition to CLOSE within the specified period of time.
During bootup/routine processing/M-Utility, the convergence path changeover guide drive motor (MB3) is driven
to perform path changeover operation (feed/load conveyor unit) after IP erasure; however, the convergence path
changeover sensor (SB10) does not transition to CLOSE within the specified period of time.
Occurrence Condition
CR-IR 363 Service Manual
MT-17
Analysis
Flow
{MT:4.6}
{MT:4.6}
{MT:4.6}
{MT:4.6}
{MT:4.7}
{MT:4.7}
{MT:4.44}