FujiFilm PROFECT CS Service Manual page 190

Table of Contents

Advertisement

Error
Error Name
Code
12202
Leading-edge detection error
12203
SCN sync signal error
12204
Polygon index signal error
12210
Polygon time-out
12211
PMT analog power supply error
12212
Laser light intensity error
12213
Polygon lock error
12214
Polygon rotation error
12215
PLL function error
12216
Start-point interval error
High-voltage command value
12217
error
12218
High-voltage detection value error
12222
Laser drive current value error
011-202-11E
06.29.2012 FM6046
During bootup, only error for the leading-edge detection signal (SED1L) is detected.
During bootup, an SCN board diagnostic error (no main-scan sync signal is generated) associated with polygon
error occurs.
During bootup, an SCN board diagnostic error (no polygon index signal is generated) associated with polygon error
occurs.
During bootup or during routine processing, the polygon OK signal cannot be detected within 7.5 seconds after the
polygon is turned ON.
During bootup and routine processing, error for the PMT analog power supply signal (+15VOKH, +15VOKL) is
detected.
During bootup and routine processing, error for the laser OK signal (LD1OKH, LD1OKL) is detected.
During bootup and routine processing, error for the polygon lock signal (POKL, PONL) is detected.
During bootup and routine processing, error is detected for the polygon rotation detection function on the SCN17A/
SCT17B board.
During bootup and routine processing, error is detected for the PLL function on the SCN17A/SCT17B board.
During bootup and routine processing, error is detected for the start-point interval function on the SCN17A/SCT17B
board.
During bootup and routine processing, error is detected for the high-voltage command value diagnostics signal on
the SCN17A/SCT17B board.
During bootup and routine processing, error is detected for the high-voltage detection value diagnostics signal on
the SCN17A/SCT17B board.
During bootup and routine processing, the laser drive current value (LDIF) is more than 1.4 times the factory default
value.
Occurrence Condition
CR-IR 363 Service Manual
MT-33
Analysis
Flow
{MT:5.14}
{MT:5.8}
{MT:5.8}
-
{MT:5.12}
{MT:5.7}
{MT:5.8}
{MT:5.19}
{MT:5.19}
{MT:5.19}
{MT:5.19}
{MT:5.19}
{MT:5.15}
MT-33