FujiFilm PROFECT CS Service Manual page 207

Table of Contents

Advertisement

Error
Error Name
Code
12860
Power supply C error 1
12861
Power supply C error 2
12862
Power supply D error
12863
Power supply D021 error
Power supply D series detection
12864
error
12871
Power supply G011 error
12872
Power supply G021 error
12873
Power supply G031 error
12874
Power supply G041 error
12875
Power supply G051 error
12881
Power supply H011 error
SCN17A/SCT17B board fuse (F2)
12881
error
12886
Power supply J011 error
011-202-11E
06.29.2012 FM6046
During bootup and during routine processing, it is detected that the voltage of the DRV17A-related +5V power
supply is not outputted.
During bootup and during routine processing, it is detected that the voltage of the DRV17B-related +5V power
supply is not outputted.
During bootup and during routine processing, it is detected that the voltage of +15V (D) power supply is not ouput
on the DRV17A board.
During bootup and during routine processing, it is detected that the "D021" fuse (F19) on the DRV17A board is
blown.
During bootup and during routine processing, even though it is detected that the voltage of +15V (D) power supply
is not output, the output is detected at a detection point of "D021" on the DRV17A board.
During bootup and during routine processing, it is detected that the "G011" fuse (F3) on the SCN17A/SCT17B board
is blown.
During bootup and during routine processing, it is detected that the "G021" fuse (F4) on the SCN17A/SCT17B board
is blown.
During bootup and during routine processing, it is detected that the "G031" fuse (F8) on the SCN17A/SCT17B board
is blown.
During bootup and during routine processing, it is detected that the "G041" fuse (F1) on the SCN17A/SCT17B board
is blown.
During bootup and during routine processing, it is detected that the "G051" fuse (F7) on the SCN17A/SCT17B board
is blown.
During bootup and during routine processing, it is detected that the "H011" fuse (F2) on the SCN17A/SCT17B board
is blown.
During bootup and during routine processing, it is detected that the "H011" fuse (F2) on the SCN17A/SCT17B board
is blown.
During bootup and during routine processing, it is detected that the "J011" fuse (F6) on the SCN17A/SCT17B board
is blown.
Occurrence Condition
CR-IR 363 Service Manual
MT-50
Analysis
Flow
{MT:9.}
{MT:9.}
{MT:9.}
{MT:9.}
{MT:9.}
{MT:9.}
{MT:9.}
{MT:9.}
{MT:9.}
{MT:9.}
{MT:9.}
{MT:9.}
{MT:9.}
MT-50

Advertisement

Table of Contents
loading

This manual is also suitable for:

Clearview csClearview csmCr-ir 363

Table of Contents