FujiFilm PROFECT CS Service Manual page 314

Table of Contents

Advertisement

10.5.2
Check Procedures via LEDs on the SNS Board (2)
1.
Perform the procedures for starting the LED check.
{MT:10.3.1_Procedures for Starting the LED Check}
2.
Check the display of the LEDs located on the SNS17B board.
3.
Navigate on the LCD panel of the RU to enter the "Erasure" Mode.
{Instruction Manual}
011-202-04
11.15.2004 FM4425
4.
Set a cassette corresponding to the sensor to be checked.
Cassette insertion
I/O No
destination
SA5
Shelf 1
SB1
SA11
Shelf 2
SB2
SA17
Shelf 3
SB3
SA23
Shelf 4
SB4
REFERENCE
To check the SG2 (11" x 14" size determination sensor), set a 11" x 14" size
cassette.
5.
Check the display of the LEDs located on the SNS17B board.
Make sure that the LEDs change (from ON to OFF, or from OFF to ON) during
operation.
l GOOD indication
The LEDs change.
l NO GOOD indication
The LEDs do not change.
6.
Perform the procedures for exiting the LED check.
{MT:10.3.2_Procedures for Exiting the LED Check}
CR-IR 363 Service Manual
MT-157
Cassette insertion
I/O No
destination
SB5
SB6
SB10
SC3
Set the cassette on any
SD2
shelf.
SE1
SE2
SG1
SG2
MT-157