Error
Error Name
Code
Switchback unit IP conveyance
10354
error (1)
Switchback unit IP conveyance
10355
error (2)
Switchback unit IP conveyance
10356
error (3)
into Erasure unit IP transporting
10357
retry error
10358
Erasure unit IP ejection error
Post-erasure feed/load unit IP
10359
conveyance error (1)
10360
Load IP conveyance error (1)
Post-erasure path guide status
10361
error (1)
011-202-04
11.15.2004 FM4425
During bootup/routine processing, the branch path changeover guide drive solenoid (SOLE1) and IP transport motor
(ME1) are driven for IP switchback operation, but the CLOSE state of the post-reading conveyance standby IP
sensor (SE1) is detected.
During routine processing, the IP transport motor (ME1) is driven for IP switchback operation, but the CLOSE state
of the post-reading conveyance standby IP sensor (SE1) is detected before the switchback standby IP sensor (SE2)
transitions to OPEN.
During routine processing, the IP erasure processing conveyance ends by driving the IP conveyance motor (ME1),
however, the CLOSE of the switchback standby IP sensor (SE2) is detected, so that the system goes down.
Although the IP transport motor (ME1) operation was retried three times for IP conveyance (erasure conveyor)
during routine processing, the switchback standby IP sensor (SE2) was closed because the IP did not pass the
sensor within the specified time.
During routine processing, the IP transport motor (ME1) is driven to convey the IP to the feed/load conveyor unit,
but the pre-convergence IP sensor (SB6) does not transition to CLOSE within the specified period of time.
During bootup/routine processing, the IP transport motor (ME1, MB1, MB2) is driven to convey the IP to the cassette
after the IP is erased; however, the pre-BCR IP sensor (SB5) does not transition to CLOSE within the specified
period of time.
During bootup/routine processing, the IP transport motor (ME1, MB1, MB2) is driven to convey the IP to the cassette
after the IP is erased, and the pre-BCR sensor (SB5) transitions to CLOSE; however, the IP feed/load sensor
(SB1/2/3/4) for the shelf of interest does not transition to CLOSE within the specified period of time.
During bootup/routine processing, the IP transport motor (ME1, MB1, MB2) is driven to eject the IP to the cassette
after the IP is erased; however, the IP feed/load sensor (SB1/2/3/4) transitions to CLOSE before the CLOSE state of
the pre-BCR IP sensor (SB5) is detected.
Occurrence Condition
CR-IR 363 Service Manual
MT-16
Analysis
Flow
{MT:4.5}
{MT:4.5}
{MT:4.27}
{MT:4.27}
{MT:4.27}
{MT:4.6}
{MT:4.6}
{MT:4.6}
MT-16

Advertisement