FujiFilm PROFECT CS Service Manual page 192

Table of Contents

Advertisement

Error
Error Name
Code
12263
Polygon rotation error (3)
12264
Polygon rotation error (4)
12270
LDIFMAX update
12271
Laser unlit error (1)
12272
Insufficient laser light intensity
12273
Laser life warning
12281
Start-point detection error (1)
12282
Start-point detection error (2)
011-202-11E
06.29.2012 FM6046
During bootup, only error for the lock signal (POKL, PONL) from the polygonal mirror (POL) is detected (detail code:
002001).
If error for the SEDTM or FCLKTM signal on the SCN17A/SCT17B board is detected, the detail code is 002003.
During bootup or during routine processing, error for the signals (PONL, POKL, PINDXL) from the polygonal mirror
and the SEDTM signal on the SCN17A/SCT17B board is detected (detail code: 001002).
Alternatively, error for the index signal (PINDXL) from the polygonal mirror and the SEDTM and FCLKTM signals on
the SCN17A/SCT17B board is detected (detail code: 001000).
Alternatively, error for the signals (POKL, PINDXL) from the polygonal mirror and the SEDTM signal on the
SCN17A/SCT17B board is detected (error code: 101000).
During routine processing, a change by 5 mA or more in LD driving current value is detected when controlling an
insufficient light quantity (to keep the light quantity of the similar level) due to degradation of the LD.
During routine processing, the laser (LDD) and start-point detection (SYN) functions are disabled due to blow of the
fuse (G011 and H011 on the SCN17A/SCT17B board) or laser failure (detail code: 805413, C05413, 00503).
During routine processing, the laser light intensity is less than 50%, and the laser light intensity error signal (LD1OKL,
LD1OKH) is detected (detail code: 004000).
Alternatively, the laser light intensity error signal (LD1OKL, LD1OKH) and laser drive current value (LDIF) error are
detected (detail code: 014000).
During routine processing, the laser drive current value (LDIF) is more than 1.4 times the factory default value.
During bootup, the disabled state of the start-point detection (SYN) function, and error for the PLL function and
polygon rotation detection function on the SCN17A/SCT17B board are detected (detail code: 801C03).
Alternatively, the disabled state of the start-point detection (SYN) function, and error for the PLL function on the
SCN17A/SCT17B board are detected (detail code: 800C03).
Alternatively, during routine processing, the disabled state of the start-point detection (SYN) function, and error for
the PLL function and polygon rotation detection function on the SCN17A/SCT17B board are detected (detail code:
801401).
During bootup and routine processing, only error for the start-point interval function on the SCN17A/SCN17B board
is detected (detail code: 000400).
Alternatively, error for the start-point interval function and polygon rotation detection function on the SCN17A/
SCN17B board is detected (detail code: 001401).
Occurrence Condition
CR-IR 363 Service Manual
MT-35
Analysis
Flow
{MT:5.8}
{MT:5.8}
-
{MT:5.9}
{MT:13.}
{MT:5.15}
{MT:5.10}
{MT:5.10}
MT-35