FujiFilm PROFECT CS Service Manual page 196

Table of Contents

Advertisement

Error
Error Name
Code
FFM motor rpm out of
12348
specification
12350
SE2 IP sensor status warning
into Erasure unit IP transporting
12357
retry warning
Post-erasure feed/load unit IP
12359
conveyance error
12360
Load IP conveyance error (1)
12363
Load IP conveyance error (4)
12366
Load IP suction retry (1)
12367
Load IP suction retry (2) (drop)
12368
IP-load air leak warning
12369
Path guide HP detection retry (1)
011-202-11E
06.29.2012 FM6046
During routine processing except for secondary erasure, the motor rotation W.F. error of the subscanning motor (MZ1)
for the W.F. monitoring operation is detected.
During bootup/routine processing, the IP transport motor (MD2, ME1) is driven to convey the IP to the erasure
conveyor unit after the IP is read, and the post-reading conveyance standby IP sensor (SE1) transitions to CLOSE;
however, the switchback standby IP sensor (SE2) does not transition to CLOSE within the specified period of time.
Although the IP transport motor (ME1) was driven for IP conveyance (erasure conveyor) during routine processing,
the switchback standby IP sensor (SE2) was closed because the IP did not pass the sensor within the specified
time. Consequently, the IP transport motor (ME1) operation was retried.
During bootup/routine processing, the IP transport motor (ME1, MB1, MB2) is driven to convey the IP to the cassette
after the IP is erased; however, the pre-BCR IP sensor (SB5) does not transition to CLOSE within the specified
period of time. Therefore, a retry was performed.
During bootup/routine processing, the IP transport motor (ME1, MB1, MB2) is driven to convey the IP to the cassette
after the IP is erased, and the pre-BCR sensor (SB5) transitions to CLOSE; however, the IP feed/load sensor
(SB1/2/3/4) for the shelf of interest does not transition to CLOSE within the specified period of time. Therefore, a
retry was performed.
During bootup/routine processing, the IP transport motor (ME1, MB1, MB2) is driven to convey the IP to the feed/
load conveyor unit after the IP is erased; however, the pre-BCR IP sensor (SB5) does not transition to OPEN within
the specified period of time. Therefore, a retry was performed.
During bootup/routine processing/M-Utility/abnormality processing, the IP suction pump (PA1/2/3/4) is driven to
return the processed IP to the cassette; however, the suction sensor (SA5/11/17/23) does not transition to OPEN
within the specified period of time, thus resulting in a suction retry.
During bootup/routine processing/M-Utility, the IP suction pump (PA1/2/3/4) is driven to perform IP load conveyance,
and the suction sensor (SA5/11/17/23) transitions to OPEN; however, the SA5/11/17/23 transitions to CLOSE (IP
drop) during IP load conveyance, thus resulting in a suction retry.
During bootup/routine processing/M-Utility/abnormality processing, the IP lead valve (SVA1/2/3/4) is driven to return
the processed IP from the feed/load conveyor unit to the cassette, and the IP suction pump (PA1/2/3/4) is stopped;
however, the suction sensor (SA5/11/17/23) does not transition to CLOSE within the specified period of time.
During bootup/routine processing/M-Utility, the convergence path changeover guide drive motor (MB3) is driven to
perform home-positioning of the path changeover guide (feed/load conveyor unit); however, the path changeover
HP sensor (SB11) does not transition to CLOSE within the specified period of time, thus resulting in a retry.
Occurrence Condition
CR-IR 363 Service Manual
MT-39
Analysis
Flow
{MT:4.29}
{MT:4.30}
{MT:4.27}
{MT:4.6}
{MT:4.6}
{MT:4.6}
{MT:4.26}
{MT:4.26}
{MT:4.41}
{MT:4.7}
MT-39

Advertisement

Table of Contents
loading

This manual is also suitable for:

Clearview csClearview csmCr-ir 363

Table of Contents