FujiFilm PROFECT CS Service Manual page 182

Table of Contents

Advertisement

Error
Error Name
Code
Initialization subscanning unit IP
10458
ejection error (2)
Initialization IP position
10459
information error
Initialization IP load conveyance
10460
error (1)
Initialization IP load conveyance
10461
error (2)
Initialization IP load conveyance
10462
error (3)
Forbidden response from Start-
10463
Read command CL
10694
Back-side H8 CPU version error
10700
SDRAM test error
10710
File open error
10732
INV23A board position error
10799
CPU bus error
11200
Initialization HV-OFF status
11273
Laser life warning
011-202-11E
06.29.2012 FM6046
During bootup, the IP transport motor (MC3) is driven to perform the remaining IP search processing; however, the
post-reading conveyance IP sensor (SD2) does not transition to OPEN within the specified period of time.
During bootup, the CMOS information of the machine (IP found) does not coincide with the remaining IP search
processing result (IP not found) so that the system goes down by user selection.
During bootup, when an IP is loaded into the cassette, the IP feed/load sensor (SB1/2/3/4) on the shelf of interest
does not transition to OPEN within the specified period of time.
During bootup, when an IP is loaded into the cassette from the erasure conveyor unit, the pre-BCR IP sensor (SB5)
does not transition to CLOSE within the specified period of time.
During bootup, when an IP is loaded into the cassette from the erasure conveyor unit, the IP feed/load sensor
(SB1/2/3/4) does not transition to OPEN within the specified period of time.
Operation is interrupted as the forbidden response is received from the CL while the RU is retrying to read and
convey. Processing is interrupted as the forbidden response is received from the CL although the Start-Read
command was transmitted from the RU.
During bootup, an invalid H8 CPU version on the SCT17B is detected.
During bootup, the SDRAM, or main memory of the CPU91A board, is tested, and a retry is executed twice, but
error is detected.
During bootup, when the file is loaded from the FLASH ROM on the IMG17A/IMG17B board into the SDRAM, error
is detected for the file residing in the FLASH ROM. Alternatively, an error is detected for the file residing in the
SDRAM.
When the ERS board conducted a diagnostic check during bootup, it was found that the INV23A board was not
mounted in the correct position.
During bootup or during routine processing, a bus error for the main CPU on the CPU91A board is detected.
During bootup, HV(high voltage) on PMT17A/PMR17B board is OFF.
During bootup, the laser drive current value (LDIF) is more than 1.4 times the factory default value.
Occurrence Condition
CR-IR 363 Service Manual
MT-25
Analysis
Flow
{MT:4.35}
{MT:4.36}
{MT:4.6}
{MT:4.6}
{MT:4.6}
-
{MT:18.}
{MT:18.}
-
-
{MT:18.}
{MT:13.}
{MT:5.15}
MT-25