FujiFilm PROFECT CS Service Manual page 179

Table of Contents

Advertisement

Error
Error Name
Code
10435
Dust removal operation error (1)
10436
Dust removal operation error (2)
10437
Dust removal operation error (3)
10438
Dust removal operation error (4)
10439
Dust removal operation error (5)
Initialization convergence path IP
10440
conveyance error (1)
Initialization convergence path IP
10441
conveyance error (2)
Initialization convergence path IP
10442
conveyance error (3)
011-202-04
11.15.2004 FM4425
During M-Utility, the dust removal motor (MZ3) is driven (clockwise) to perform dust removal operation; however, the
dust removal HP sensor (SZ4) does not transition to CLOSE within the specified period of time.
During M-Utility, the dust removal motor (MZ3) is driven (clockwise) to perform dust removal operation; however, the
dust removal HP sensor (SZ4) does not transition to OPEN within the specified period of time.
During M-Utility, the dust removal motor (MZ3) is driven (counterclockwise) to perform dust removal operation;
however, the dust removal HP sensor (SZ4) does not transition to CLOSE within the specified period of time.
During M-Utility, the dust removal motor (MZ3) is driven (counterclockwise) to perform dust removal operation;
however, the dust removal HP sensor (SZ4) does not transition to OPEN within the specified period of time.
During routine processing, the IP stopper drive motor (MZ4) is driven (clockwise) to perform the system shutdown
processing; however, the dust removal HP sensor (SZ4) does not transition to CLOSE within the specified period of
time.
During bootup, the IP transport motor (MB1, MB2, MC3) is driven to perform the remaining IP search processing;
however, the side-positioning entrance IP sensor (SG1) and pre-convergence IP sensor (SB6) do not transition to
OPEN within the specified period of time.
During bootup, the IP transport motor (MB1, MB2, ME1) is driven to perform the remaining IP search processing;
however, the side-positioning entrance IP sensor (SG1) does not transition to CLOSE within the specified period of
time.
Alternatively, the pre-BCR IP sensor (SB5) and pre-convergence IP sensor (SB6) do not transition to OPEN within
the specified period of time.
During bootup, the IP transport motor (MB1, MB2, MC3) is driven to perform the remaining IP search processing;
however, the side-positioning entrance IP sensor (SG1) and pre-BCR IP sensor (SB5) do not transition to OPEN
within the specified period of time.
Alternatively, the pre-convergence IP sensor (SB6) does not transition to CLOSE within the specified period of time.
Occurrence Condition
CR-IR 363 Service Manual
MT-22
Analysis
Flow
{MT:4.17}
{MT:4.17}
{MT:4.17}
{MT:4.17}
{MT:4.42}
{MT:4.18}
{MT:4.18}
{MT:4.18}
MT-22

Advertisement

Table of Contents
loading

This manual is also suitable for:

Clearview csClearview csmCr-ir 363

Table of Contents