FujiFilm PROFECT CS Service Manual page 175

Table of Contents

Advertisement

Error
Error Name
Code
Side-positioning unit grip HP
10374
detection error
Post-reading conveyor unit grip
10378
HP detection error
Erasure unit grip HP detection
10382
error
Side-positioning unit side-
10386
positioning mechanism HP
detection error
Erasure unit side-positioning
10390
mechanism HP detection error
10394
Suction cup HP detection error
10398
Cleaning guide HP detection error
011-202-04
11.15.2004 FM4425
During bootup/M-Utility, the grip release motor (MC2) is driven to perform grip home-positioning of the side-
positioning conveyor unit; however, the OPEN or CLOSE of the grip release HP sensor (SC2) is not detected. After
two retries are executed, this is not detected, so that the system goes down.
During bootup/M-Utility, the grip release motor (MD1) is driven to perform grip home-positioning of the post-reading
conveyor unit; however, the OPEN or CLOSE of the grip release HP sensor (SD1) is not detected. After two retries
are executed, this is not detected, so that the system goes down.
During bootup/M-Utility, the grip release motor (ME3) is driven to perform grip home-positioning of the erasure
conveyor unit; however, the OPEN or CLOSE of the grip release HP sensor (SE5) is not detected. After two retries
are executed, this is not detected, so that the system goes down.
During bootup/routine processing/M-Utility, the side-positioning motor (MC1) is driven to perform side-positioning
mechanism home-positioning of the side-positioning conveyor unit; however, the OPEN or CLOSE of the side-
positioning mechanism HP sensor (SC1) is not detected. After two retries are executed, this is not detected, so that
the system goes down.
During bootup/routine processing/M-Utility, the side-positioning motor (ME2) is driven to perform side-positioning
mechanism home-positioning of the erasure conveyor unit; however, the OPEN or CLOSE of the side-positioning
mechanism HP sensor (SE4) is not detected. After two retries are executed, this is not detected, so that the system
goes down.
During bootup/routine processing/M-Utility, the suction cup drive motor (MA1/2/3/4) is driven to perform suction cup
home-positioning; however, the OPEN or CLOSE of .the suction cup HP sensor (SA4/10/16/22) is not detected.
After two retries are executed, this is not detected, so that the system goes down.
During bootup/M-Utility, the cleaning guide drive motor (MC4) is driven to perform home-positioning of the cleaning
guide; however, the OPEN or CLOSE of the cleaning guide HP sensor (SC4) is not detected. After two retries are
executed, this is not detected, so that the system goes down.
Occurrence Condition
CR-IR 363 Service Manual
MT-18
Analysis
Flow
{MT:4.8}
{MT:4.9}
{MT:4.10}
{MT:4.11}
{MT:4.33}
{MT:4.12}
{MT:4.13}
MT-18