FujiFilm PROFECT CS Service Manual page 168

Table of Contents

Advertisement

Error
Error Name
Code
10014
File close error (2)
10060
Device open error
Barcode reader communication
10061
error
S c a n n e r B U S Y c o n f i r m a t i o n
10062
timeout
10063
Scanner command timeout
10064
"CPU-SCN" command retry over
Image processing CPU error
10065
during operation
10066
IMG board type error
10067
Image processing CPU type error
10070
Socket error
10090
FLASH-ROM access error
011-202-05
05.09.2005 FM4610
During bootup, when the file is loaded from the FLASH ROM on the IMG17A/IMG17B board into the SD RAM, error
is detected for the file residing in the FLASH ROM. Alternatively, an error is detected for the file residing in the SD
RAM.
When an attempt is made to operate a motor or the like during bootup or routine processing, the specified device
cannot be opened.
During bootup or during routine processing, communication error occurs between the CPU91A board and barcode
reader (BCR), so that communication cannot be established.
During bootup or during routine processing, the status of the scanner board is checked before sending a command
from the CPU91A board to the scanner board (SCN17A/SCT17B), but it is in BUSY state.
During bootup and routine processing, a timeout occurs for communication between the main CPU (CPU91A board)
and scanner H8CPU (SCN17A/SCT17B board).
During bootup or during routine processing, a command is sent from the CPU91A board to the SCN17A/SCT17B
board, but a retry-over occurs.(Retry; three times)
During routine processing, because the data sent from the "IMG17A/B board: sub-CPU" has an insufficient or
excess number of pixels, the software performs processing to supplement or cut the insufficient or excess number
of pixels in the line direction.
During bootup, an invalid IMG board is detected. (IMG17A board is installed in CR-IR 363.)
<Action>
Check the IMG board. Mount the IMG17B board if a different board has been mounted.
An out-of-definition version is detected in the image processing CPU of the IMG17A/IMG17B board during bootup.
Various types of error occur for the socket communication which is used to establish a network connection between
the RU and CL.
During bootup or during Maintenance Utility, the FLASH ROM on the IMG17A/IMA17B board is accessed, but error
is detected.
Occurrence Condition
CR-IR 363 Service Manual
MT-11
Analysis
Flow
{MT:18.}
{MT:18.}
{MT:18.}
{MT:18.}
{MT:18.}
{MT:18.}
{MT:18.}
-
-
{MT:14.}
{MT:18.}