Error
Error Name
Code
10261
Polygon rotation error (1)
10271
Laser unlit error (1)
10281
Start-point detection error (1)
Scanning optics unit board error
10283
(1)
10293
Printed board type error
10294
H8 CPU version error
10298
Scanner retry error
10343
IP barcode reading retry error (2)
10344
IP barcode reading retry error (1)
011-202-04
11.15.2004 FM4425
During bootup, error for the polygon lock signal (PONL, POKL) is detected so that the polygonal mirror function is
disabled. The start-point detection (SYN) and leading-edge detection (SED) functions are also disabled (detail code:
903403, 003400, 902403).
During bootup, the laser (LDD) and start-point detection (SYN) functions are disabled due to blow of the fuse (G011
and H011 on the SCN17A/SCT17B board) or laser failure (detail code: 805413, C05413, 00503).
During routine processing or during self-diagnostics, because the signal from the start-point detection (SYN) is
faulty, the SCN17A/SCT17B board does not operate normally (detail code: 801C03).
For self-diagnostics prior to reading during routine processing, the SCN17A/SCN17BA board diagnostic error
associated with polygon error is detected.
The laser is unlit due to a disconnected connector at the scanning optics unit, etc., so that an error related to the
polygon error occurs, as well.
During bootup, an invalid SCN board type is detected. (SCN17A board is installed in CR-IR 363.)
<Action>
Check the scanner board. Mount the SCT17B board if a different board has been mounted.
During bootup, an invalid H8CPU version on the SCN17A/SCT17B is detected.
During bootup, because the scanner-related error is detected, the IP is returned to the cassette and the scanner is
initialized.
The routine processing is retried again, but the scanner-related error recurs.
During routine processing, the IP transport motor (MB2, MC3) is driven for barcode reading retry operation (return
conveyance), but the side-positioning entrance IP sensor (SG1) does not transition to CLOSE within the specified
period of time.
During routine processing, the IP transport motor (MC3) is driven for barcode reading retry operation, but the side-
positioning IP sensor (SC3) does not transition to CLOSE within the specified period of time.
Occurrence Condition
CR-IR 363 Service Manual
MT-14
Analysis
Flow
{MT:5.8}
{MT:5.9}
{MT:5.10}
{MT:5.8}
-
{MT:5.15}
{MT:5.11}
{MT:4.1}
{MT:4.1}
MT-14