FujiFilm PROFECT CS Service Manual page 273

Table of Contents

Advertisement

5.11
Error Code Analysis Flow: Scanner 11
10298, 12298
n Analysis Flow
m
Check the error log in the ERROR DB.
Q1
Errors 10230-10236 logged?
Y
Check the error code table again and troubleshoot.
N
{MT:2._Error Code Table}
A
Q2
Other software exited before RU startup?
N
Exit the other software.
Y
Q3
Check the voltage of the SCN17A/SCT17B board test pin (CN5).
{MT:8._Procedures for Checking the Voltage}
Q4
Check all the fuses on the SCN17A/SCT17B board.
{MT:9._Procedures for Checking the Fuses}
Q5
Error recurs?
N
A
Y
Q6
IMG17A/B, CPU91A, and SCN17A/SCT17B boards tested in MUTL normal?
{MT:18._Board Test in MUTL}
N
Q9
Y
Q7
011-202-04
11.15.2004 FM4425
Q7
Perform the diagnostics.
{MU:5.3
[5-1]_Diagnostic}
Q8
Error recurs?
N
A
Y
m
Disconnect and reconnect the connectors in the following sequence. If the error is
detected, replace the affected part.
1. SCN17A/SCT17B board
{MC:13.4_Scanner Board}
2. CPU91A board
{MC:13.2_CPU91A Board}
3. IMG17A/B board
{MC:13.3_IMG17A/B Board}
Q9
Reseat the error-causing board and check if the error occurs again.
N
A
Y
m
Replace the error-causing board.
{MC:13.2_CPU91A Board}
{MC:13.3_IMG17A/B Board}
{MC:13.4_Scanner Board}
CR-IR 363 Service Manual
MT-116
MT-116

Advertisement

Table of Contents
loading

This manual is also suitable for:

Clearview csClearview csmCr-ir 363

Table of Contents